Product Highlight
Note
(1) LEDs (5) AC Socket
(2) One Console port (6) one Management 0/0 interface
(3) Two USB Ports (7) I/O slot
(4) Eight Gigabit Ethernet data interfaces
Thông số kỹ thuật Firewall Cisco ASA5545-FPWR-K9
Capabilities and Capacities | |
Throughput: Application Control (AVC) |
1,500 Mbps |
Throughput: Application Control (AVC) and IPS |
1,000 Mbps |
Maximum concurrent sessions | 750,000 |
Maximum New Connections per second | 30,000 |
Supported applications | More than 3,000 |
URL categories | 80+ |
Number of URLs categorized | More than 280 million |
Centralized configuration, logging, monitoring, and reporting | Multi-device Cisco Security Manager (CSM) and Cisco Firepower Management Center |
On-Device Management | ASDM (version 7.3 or higher required) |
Features and Capacities | |
Stateful inspection throughput (maximum) | 3 Gbps |
Stateful inspection throughput (multiprotocol) | 1.5 Gbps |
Triple Data Encryption Standard/Advanced Encryption Standard (3DES/AES) VPN throughput | 400 Mbps |
Users/nodes | Unlimited |
IPsec site-to-site VPN peers | 2500 |
Cisco AnyConnect Plus/Apex VPN maximum simultaneous connections | 2500 |
Virtual interfaces (VLANs) | 300 |
Security contexts (included; maximum) | 2; 50 |
High availability | Active/Active and Active/Standby |
Integrated Wireless Access Point (See Cisco AP 702 datasheet for WiFi technical details) |
N/A |
Expansion slot |
1 interface card |
User-accessible Flash slot |
0 |
USB 2.0 ports |
2 |
Integrated I/O |
8 GE copper |
Expansion I/O |
6 GE copper or 6 GE Small Form-Factor Pluggable (SFP) |
Dedicated management port |
Yes (1 GE) |
Serial ports |
1 RJ-45 console |
Solid-state drive |
2 slots, RAID 1, 120 GB MLC SED |
Memory |
12 GB |
System flash |
8 GB |
System bus |
Multibus architecture |
Operating Parameters |
|
Temperature | 23 to 104°F (-5 to 40°C) |
Relative humidity | 90 percent |
Altitude | Designed and tested for 0 to 10,000 ft (3050 m) |
Acousticnoise | 67.9 dBA max |
Non-operating Parameters | |
Temperature | -13 to 158ºF (-25 to 70ºC) |
Relative humidity | 10 to 90 percent noncondensing |
Altitude | Designed and tested for 0 to 15,000 ft (4572 m) |
Power Input (per power supply) | |
AC range line voltage | 100 to 240 VAC |
AC normal line voltage | 100 to 240 VAC |
AC current | 5A, 100 to 120V, 2.5A, 200 to 240V |
AC frequency | 50/60 Hz |
Dual-power supplies | Yes |
DC domestic line voltage | -40.5 to 56 volts direct current (VDC) (-48 VDC nominal) |
DC international line voltage | -55 to -72 VDC (-60 VDC nominal) |
DC current | 15A (maximum input) |
Output | |
Steady state | 86W |
Maximum peak | 125W |
Maximum heat dissipation | 427 Btu/hr |
Form factor | 1 rack unit (RU), 19-in. rack-mountable |
Dimensions (H x W x D) | 1.67 x 16.7 x 19.1 in. (4.24 x 42.9 x 48.4 cm) |
Weight (with AC power supply) | 16.82 lb (7.63 kg) with single power supply 18.86 lb (8.61 kg) with dual power supply |