Giá | |
Bảo hành | :12 tháng |
Port | :Update |
POE | : Không xác định |
Throughput | : Không xác định |
Power | : Không xác định |
: 1667 |
Feature | Specification | |
Substation hardening compliance | IEC 61850-3 IEEE1613 | |
Embedded hardware-based cryptography acceleration (IPSec + SSL) | Yes | |
Total onboard Combo Ethernet WAN Ports | 2 | |
Grid Router WAN Interface Card (GRWIC) slots | 4 | |
Double-wide capable GRWIC slots (use of a double- wide GRWIC slot will consume two GRWIC slots) | 2 | |
Memory DDR2 ECC DRAM - default | 1 GB | |
Rugged compact flash | slot 0: 256 MB (Default) slot 1: 256 MB (Optional Expansion for storage) | |
External USB 2.0 flash memory slots (Type A) | 2 | |
USB Console port (Type B) (up to 115.2 kbps) | 1 | |
Serial console port | 1 | |
Serial auxiliary port | 1 | |
Power supply options | Two power supply options: - Low-voltage DC power supply (available in late 2010) - AC or high-voltage DC power supply Any combination of power supplies can be inserted into the chassis. Dual power supply configurations are load sharing in redundancy mode, although a single power supply is sufficient for supporting power needs for the system. | |
Power specifications | ||
AC input voltage (Power Supply Unit 1) | Nominal Range: 100 - 240 VAC Operating Range: 85 -264 VAC AC supply also accepts a DC input with an operating range of 88 - 300 VDC | |
DC input voltage (Power Supply Unit 2) | Nominal Range: 24 - 60 VDC Operating Range: 20 - 75 VDC | |
AC input frequency | 47 to 63 Hz | |
AC input current range for AC power supply (maximum) | 2 A | |
AC input surge current | <50 A | |
DC input voltage | 24 - 60 VDC, extended 88-300 VDC (on separate power supply) | |
System power consumption (with no modules) (Watts) | 30 Watts | |
Grid Router WIC power consumption | Typical: 4.5 Watts Maximum: 6 Watts | |
Physical specifications | ||
Dimensions (H x W x D) | 3.5 x 17.25 x 15 in. (88.9 x 438.2 x 381 mm) | |
Rack height | 2 RU (rack unit) | |
Rack-mount 19 in. (48.3 cm) EIA | Included | |
Wall-mount | Yes | |
Weight with 1 power supply (no modules) | 19 lbs (8.6kg) | |
Typical weight fully configured with 2 power supplies and 4 GRWICs | 25 lbs (11.4 kg) | |
Airflow | Convection and conduction cooling (no fans) | |
Environmental Specifications | ||
Operating Conditions | ||
Operating Temperature | -40 ºF to 140ºF (-40 to +60ºC) continuous operating temperature range -40 ºF to 185ºF (-40 to +85ºC) type test for 100 hours at 85ºC | |
Shock/Vib | 30G @11 ms | |
Altitude | 10,000 ft (3,048 m) Max operating temp is de-rated with increasing altitude per IEEE 1613-2009 | |
Relative humidity | 5 to 95% non-condensing | |
Non-operating conditions | ||
Temperature | -40ºF to 185ºF (-40ºC to 85ºC) | |
Relative humidity | 5 to 95% non-condensing | |
Altitude | 16,000 ft (4,876 m) Max operating temp is de-rated with increasing altitude per IEEE 1613a-2008 | |
Non-Op Free Fall Drop | 4 in. (100 mm) per ENG-339611 | |
Operating seismic/earthquake | NEBS GR-63 (5.4.1) | |
Non-op shock/vib | 40-50G (3.26 m/s minimum) | |
Regulatory compliance* | ||
Environmental substation compliance | IEC-61850-3 IEEE1613 | |
Immunity | EN61000-6-2 EN61000-4-2 (ESD) EN61000-4-3 (RF) EN61000-4-4 (EFT) EN61000-4-5 (SURGE) EN61000-4-6 (CRF) EN61000-4-11 (VDI) EN 55024, CISPR 24 EN50082-1 | |
EMC | 47 CFR, Part 15 ICES-003 Class A EN55022 Class A CISPR22 Class A AS/NZS 3548 Class A VCCI V-3 CNS 13438 EN 300-386 | |
Safety | USA: UL 60950-1 Canada: CAN/CSA C22.2 No. 60950-1 Europe: EN 60950-1 China: GB 60950-1 Australia/New Zealand: AS/NZS 60950-1 Rest of World: IEC 60950-1 CSA certified to UL/CSA 60950-1, 2nd Ed. CB report to IEC60950-1, 2nd Ed., covering all group differences and national deviations | |
Telecom | US: TIA-968-A CA: CS-03 EU: TBR1, 2, 4, 12, 13 RTTE Directive Australia: AS/ASIF S016, S038 Japan: JATE | |
Telecom interface standards | T1/E1 GRWIC: ITU-T G.703, G.704, G.706, G.823, ANSI T1.403 8-port Asyn/Sync RS-232 GRWIC: RS232, ITU-T V.11 |
PWR-RGD-AC-DC= | High AC/DC (88-300VDC/85-264VAC) power supply for Cisco CGR2010 and CGS2520 switch, Spare |
PWR-RGD-LOW-DC= | Low DC (24-60VDC) power supply module for the Cisco CGR 2010 and CGS 2520 switch (available in late 2010) |
Part Number | Specification | SFP Type | Max Distance | Cable Type | Temp Range | DOM Support |
GLC-FE-100FX-RGD= | 100BASE-FX | FE | 2km | MMF | IND | Yes |
GLC-FE-100LX-RGD | 100BASE-LX10 | FE | 10km | SMF | IND | Yes |
GLC-FE-100FX= | 100BASE-FX | FE | 2km | SMF | COM | No |
GLC-FE-100LX= | 100BASE-LX10 | FE | 10km | SMF | COM | No |
GLC-FE-100EX= | 100BASE-EX | FE | 40km | SMF | COM | No |
GLC-FE-100ZX= | 100BASE-ZX | FE | 80km | SMF | COM | No |
GLC-FE-100BX-D= | 100BASE-BX10 | FE | 10km | SMF | COM | No |
GLC-FE-100BX-U= | 100BASE-BX10 | FE | 10km | SMF | COM | Yes |
GLC-SX-MM-RGD= | 1000BASE-SX | GE | 550m | MMF | IND | Yes |
GLC-LX-SM-RGD= | 1000BASE-LX/LH | GE | 550m/10km | MMF/SMF | IND | Yes |
GLC-ZX-SM-RGD= | 1000BASE-ZX | GE | 70km | SMF | IND | Yes |
GLC-SX-MMD= | 1000BASE-SX | GE | 550m | MMF | EXT | Yes |
GLC-LH-SMD= | 1000BASE-LX/LH | GE | 550m/10km | MMF/SMF | EXT | Yes |
GLC-EX-SMD= | 1000BASE-EX | GE | 40km | SMF | EXT | Yes |
GLC-ZX-SMD= | 1000BASE-ZX | GE | 70km | SMF | EXT | Yes |
GLC-BX-D= | 1000BASE-BX10 | GE | 10km | SMF | COM | Yes |
GLC-BX-U= | 1000BASE-BX10 | GE | 10km | SMF | COM | Yes |
CWDM-SFP-xxxx= (8 freq) | CWDM 1000BASE-X | GE |
| SMF | COM | Yes |
DWDM-SFP-xxxx= (40 freq) | DWDM 1000BASE-X | GE |
| SMF | COM | Yes |
SFP-GE-S= | 1000BASE-SX | GE | 550m | MMF | EXT | Yes |
SFP-GE-L= | 1000BASE-LX/LH | GE | 550m/10km | MMF/SMF | EXT | Yes |
SFP-GE-Z= | 1000BASE-ZX | GE | 70km | SMF | EXT | Yes |
GLC-SX-MM= | 1000BASE-SX | GE | 550m | MMF | COM | No |
GLC-LH-SM= | 1000BASE-LX/LH | GE | 550m/10km | MMF/SMF | COM | No |
GLC-ZX-SM= | 1000BASE-ZX | GE | 70km | SMF | COM | Yes |